↓ Skip to Main Content

Modbus polling

ESP8266 Wi-Fi tutorial and examples using the Arduino IDE
Modbus polling

Modbus polling. Profiling proved most od the time is spent on serial port access. Figure 2: Selecting the data query and parser module. net. Image used courtesy of Modbus . Modbus Optimisation). Modbus Poll is on easy to make Modbus master simulator developed for many purposes. Modbus protocol is defined as a master/slave protocol, meaning a device operating as a master will poll one or more devices operating as a slave. 点击Connection -> Connect 。按照如下设置(链接单片机后,软件自动选择,也可以手动选择。) modbus is a communication protocol to control PLCs (Programmable Logic Controller) and RTUs (Remote Terminal Unit). - ClassicDIY/ModbusTool Jan 26, 2024 · Ensure that the communication settings, including baud rate and parity, are accurately configured in Modbus Poll to match those of the Modbus devices. Supports Modbus RTU/ASCII and Modbus TCP/IP. For each window you simply specify the Modbus slave ID Jan 21, 2023 · Tutorial of using Modbus Pull#ModbusPoll#modbussid #delta industrial Automation#DVP DELTA PLC#DVP28SV11T2#industrialautomation #VFD#PLC#HMI #scadaprogramming Jan 6, 2020 · Rating: (530) Your code controls the polling interval. Jan 30, 2023 · An example of a Modbus network architecture. Export polling data to local storage for further investigation. Modbus Poll version 10. Detailed Description. With the multiple document interface you can monitor several Modbus slaves and/or data areas at the same time. See VBExample. Rilheva Modbus Poll is the best Modbus master simulator for test and debug of your slave devices. Ultimately it allows you to transition to TCP while still making use of your Modbus serial devices. WSMBT is a powerful and simple to use . 00 KB. At first, the Modbus read holding register function and write Description. It keeps disconnecting because I am not sending it a Modbus command. 0 Build 1946 là một phần mềm giả lập Modbus Master được thiết kế để giúp bạn có thể giao tiếp Description: Modbus Poll is a client simulator for test and debug of server devices. The tags are assigned to a custom Tag Group Transparent mode communication, using the traditional round-robin polling mechanism, is usually standard in the Modbus gateway market. Input Register. Home Assistant (as well as the open-source Rapid Scada software) is working to poll various “sensors” from the ESP-32 device. NET, C# or Managed C++. Image used courtesy of Figueroa-Lorenzo et al. The 16 Bit Modbus registers can be displayed in 4 different modes. For each win. Originally implemented as an application-level protocol intended to transfer data over a serial layer, Modbus has expanded to include implementations over serial, TCP/IP, and the user datagram protocol (UDP). Jan 2, 2003 · This is a modbus polling tool base on Modbus RTU protocol. Because the slave devices do not broadcast their information, the master needs to request, or ‘poll’, information about the slave. Use a single Plain English program to schedule the polling Trong một hệ thống mạng Modbus, chúng ta sẽ có 2 thành phần chính đó là Modbus master và Modbus slave. Sep 17, 2012 · 1 Answer. Anyway, you are actually reading first 10 registers in your first screenshot. Configure Modbus messages to slave 1 to go to port 1. Nov 3, 2020 · These mechanisms isolate the Modbus Polling from programs and graphics. Just be sure to wait at least 0. Nov 8, 2002 · Paul Fazio wrote: > is there a pre-set polling rate for ModbusRTU over an RS-485 serial > line? No. Try it in two different versions: Rilheva Modbus Poll Desktop Edition for Windows O. 3. If negative numbers are provided, it will precede the list of data to be written by two dashes ('--'). IsRunning = true; Modbus Protocol is a messaging structure developed by Modicon in 1979. The client supports the following modes: modbus RTU (serial, over both RS-232 and RS-485), Sep 6, 2018 · 02. poll. Slave 1 take a time to process his buffer. The problem appears to be with the slave response. WSMBT Modbus Master TCP/IP Control for . None. Originally implemented as an application-level protocol intended to transfer data over a serial layer, the protocol has expanded to include implementations over serial, TCP/IP, and the user datagram protocol (UDP). It is Modbus master simulator. Dec 23, 2021 · One way around this disadvantage is to deploy a Modbus bridge. The Moxa can go very fast in like 10 requests per seconds or more. Connectivity: Modbus RTU, Modbus ASCII, Modbus TCP/IP. A Modbus Bridge connects Modbus networks to several different protocols and networks. Quick start guide Mar 6, 2024 · To configure the polling, use the MODBUS RTU module in ASDL (Figure 2). But my original tags were 1000ms Subcribed. Native Modbus registers. 3) Slave 1: OK, this is for me. How to install wonderware SCADA Softwarehttps://youtu. This package is a go implementation of the modbus protocol. The binding has the following extensions: E3DC Sep 24, 2017 · In serial Modbus, the only way for a master to become aware of a change in a sensor or input, or the presence of an alarm, etc. Modbus Poll is the very popular Modbus master simulator for test and debug of your slave devices. This is my windows application polling the eModbus library for data. After confirming this, close PuTTY and open Modbus Poll. It aims to provide a simple-to-use, high-level API to interact with modbus devices using native Go types. modbustools. 5 sleep passed master assembles response one byte at a time. After playing around with the rate, It disconnects bettween 3000 - 4000 ms with Polled mode selected. In our case the registers are the ED device’s digital inputs. These polls can be for single values or block reads. This class realises the server-side of the Modbus RTU slave protocol. Find and set the minimum achievable Timeout, 2. is to regularly ‘poll’ a slave. It works with single inverters, multiple inverters, meters, batteries, and many other improvements over other integrations that didn't work well with a multi-device setup. > I'm trying to optimize my Modbus Slave code and I can't > decide whether I should write the slave to treat its register > banks like a cache and populate them at a regular interval, or if it > should Mar 6, 2024 · To configure the polling, use the MODBUS RTU module in ASDL (Figure 2). virtual int poll() = 0; Parameters. Display with PLC style addresses. Lets see if I have understood you correctly - you want to read the inputs (your two sensors). Trên phần mềm Modbus Pol hỗ trợ nhiều cửa sổ, người sử dụng Aug 28, 2014 · AKD-Basic-4. vbp; Read/write of up to 127 Registers; Read/write of up to 2000 Inputs/Coils; Compose Mar 6, 2021 · Modbus Poll is a Modbus primary emulator designed primarily to help Modbus device developers or others wanting to test and emulate the Modbus protocol. Hint: Leave this window open while doing other commands. Base 0. Jul 29, 2023 · Modbus đã trở thành một giao thức truyền thông tiêu chuẩn thực tế và hiện là phương tiện phổ biến để kết nối các thiết bị điện tử công nghiệp. It provides functions to start-up and to execute the server engine which includes opening and closing of the serial port. For each window you simply specify the Modbus slave ID Mobus Poll Setup. 560 seconds. It should be noted that the simulator works in Master mode. if still any query let me know in the comment box----- Download Modbus Poll. The second column name (next to Alias) contains the Start Address of registers you wish to read (in your case it's 0). 22 or later and Win32. Jan 9, 2021 · DDS90 (DDS90) January 9, 2021, 1:40pm 2. 2. The Modbus RTU X Driver can typically make 2 polls per second. Features: OLE Automation means easy interface to Visual Basic, use it almost like an ActiveX component. 一、介绍 Modbus Poll :Modbus主机仿真器,用于测试和调试Modbus从设备。 该软件支持ModbusRTU、ASCII、TCP/IP。 用来帮助开发人员测试Modbus从设备,或者其它Modbus协议的测试和仿真。 In a simple word, Modbus is a language that a device uses to communicate with other devices, software/app, and HMI device. 0 or later, QNX 4. Features of Modbus Poll. g. 04. Step 2 – Confirm Consistent Slave Address Confirm that the slave address set in Modbus Poll aligns with the assigned ID of the Modbus device under investigation. Upon receipt of a valid master query the server engine calls Data Provider methods to exchange data with the user application. Aug 14, 2020 · Early Modbus was memory-limited so addressing was so-called 5-digit addressing, limited to (4)9999 (decimal) because Modbus devices never needed more than 9,999 registers. See the Quick Start Guide. 0, 'requestsPerSec': 34. Jul 4, 2012 · To develop an asyncronous communication you need to have a thread dedicated to polling the modbus device. With the multiple document Here is a summary of the steps for configuring the Digi One IAP. Configure ASCII device on port 1 for half-duplex (weight scale). S. The answer is the same 01 03 02 02 C1 78 B4. Figure 3. MODBUS power meter data logging (easy method) Sunspec-compatible MODBUS power meters, inverters (easy method) MODBUS RTU/TCP polling: Configuring master station (MODBUS RTU, MODBUS TCP, requests, response items). Chào các bạn, hôm nay mình xin hướng dẫn các bạn cài đặt cài dặt Modbus Poll - Modbus Scanner. So you will need to setup a cycle in your code. 2023-11-19. Feature. Plus, you can leave notes in individual cells. It can be switched polling behavior by input msg. For example polling register address 40010 on function code 03 when it should have been address 9 on function code 03. Modbus Poll is a simulator designed specifically for testing the Modbus protocol in Slave devices. Note: This window show only data sent and received by Modbus Poll. Feb 23, 2024 · If you are looing for a modbus python library, please consider the following great open source projects, pymodbus or minimalmodbus. Modbus remains the most widely available protocol for connecting industrial devices. Mar 24, 2011 · 1) The master send a request to a specific slave 01 : Q01. I doubt it is an hardware limit because I’ve freshly tried to polling the same devices with the same hardware using “Modbus Poll” and mbusd like a gateway and this is the result: rossko57 (Rossko57) January 9, 2021, 3:18pm 3. I understood that if a slave receives a normal (error-free) message that it will respond. 1 file (s) 4. 03. The Modbus industrial protocol was developed in 1979 to make communication possible between automation devices. . Generate a rising edge on REQ, wait for BUSY to be set, then negate REQ, Then wait until DONE or ERROR and not BUSY, then repeat. ns=1;s=[Rotronic]Reading1). Mar 31, 2023 · Overview. The trial version is a Nov 15, 2005 · Modbus Poll Modbus Poll is a Modbus master simulator designed primarily to help developers of Modbus slave devices or others that want to test and simulate the Modbus protocol. Modsim 32의 경우 Slave에서 Modbus polling을 할 경우에 사용한다 Feb 12, 2020 · Problem: Modbus TCP device is getting polled every second, despite Tag Group settings Device: Modbus TCP connection to Rotronic room temperature monitor S/W: 8. 2+ licenses: $ 99. Base 1. If only a few meters are connected to a gateway, scan times might not be so much of an issue. Tuy nhiên, nếu các bạn đang lập trình cho thiết bị modbus slave và không có thiết bị master để test thì chương trình Modbus Poll sẽ là ứng dụng tuyệt vời để mô phỏng giống Apr 17, 2021 · #modbus#modscan#modbuspolluseThis video for don't know how to use Modbus poll . Feb 12, 2019 · Trong một hệ thống mạng Modbus, chúng ta sẽ có 2 thành phần chính đó là Modbus master và Modbus slave. If a Modbus Object value is only required for logging purposes, then the "Requested poll interval" is set to a high number (typically 2,147,483,647 ms) This means the object values are not Mar 31, 2023 · Modbus is an industrial protocol that was developed in 1979 to make communication possible between automation devices. The difference in polling speed is about 6 seconds. The modbus integration supports all devices adhering to the modbus standard. With prioritized polling, you can group your registers into different priority categories. Publish polling data to MQTT broker for remote debugging, especially on smart phone. Support Modbus RTU/TCP/UDP devices; Show polling data for local debugging, like a typical modpoll tool; Publish polling data to MQTT broker for remote debugging, especially on smart phone One of our clients was concerned about this, so we developed an Modbus-polling RTU with a prioritized polling function. Modbus tools for test, simulation and programming. 그리고 디바이스 설정에 가서 비트와 패리티를 확인한다. Quick start guide Hallo semua!!! Belajar Wonderware Yuk! Cek playlist dibawah ya!1. NET. Then replacing the Moxa with eModbus still works (Option A), but at a maximum rate of 1 message per second. With the multiple document interfaces Nov 22, 2023 · Modbus polling is a communication technique used in Supervisory Control and Data Acquisition (SCADA) systems to exchange data between a master device (such as a computer, PLC, or RTU) and multiple slave devices (sensors, actuators, or other control devices) over a Modbus network. Modbus Poll is a Modbus master that has read and write functions and has the capability of capturing communication traces. Other platforms on request. By using Modbus, we can make: Two Arduinos talk with each other to control/monitor the output/input. If the wrong format is used it can result in failure to communicate because the wrong register is used. Then generate a answer. How to enable sa acc Modpoll Modbus Polling Tool The FieldTalk(tm) utility modpoll is a command line based Modbus master simulator and test utility. When all registers in a group have been read, the response message returns subscribed register values for the whole group. You can't use it as a data sniffer. As this X Driver operates outside the regular controller scanning process, polling too many points or many points that are offline can cause the scan time to rapidly rise. And then you have your quantity of 64 regs: {'currentCpuUsage': 5. Configure ASCII device on port 2 for transmit-only (LED marquee display). Syntax. Coil. 5 seconds before timing out on the reply (Note: On WattNode firmware version 16 or later, the reply timeout can be as short as 25 milliseconds). com/drive Modbus Poll user manual. Jul 8, 2010 · Modbus Poll is a Modbus master simulator designed primarily to help developers of Modbus slave devices or others that want to test and simulate the Modbus protocol. When a window opens (Figure 3), click "Action → Add new request" to add one or more requests. Support Modbus RTU/TCP/UDP devices. The wiki file includes a tab to assess the exact performance of the Modbus polling (4. 존재하지 않는 이미지입니다. And collects responses to make the final result. Prioritized Modbus polling. openHAB commands are translated to write requests. Holding Register. Mar 24, 2023 · Modbus Poll user manual / Communication Modbus RTU. You already have the Modbus function to perform the read and it returns an array based on a starting address and quantity. 7 I am capturing two serial numbers, temp, and humidity from a Rotronic device. Provide docker solution for continuous data polling use case. Signed; Unsigned; Hex; Binary; 32 bit signed integer. 23A and QNX TCP/IP 4. Both client and server components are available. This thread listen to external calls from the application and executes reads and writes to the plc. In the original version after request is sent and T3. Although polling is simple, it takes up network bandwidth and processing time on the master and the slaves. It is used to establish client-server communication between intelligent devices. First, some slaves turn OFF their serial port when they are not being addressed. Modbus Poll is an easy to use Modbus master simulator developed for many purposes. Modbus Poll (64-Bit) is a Modbus simulator designed primarily to help developers of Modbus slave devices or others that want to test and simulate the Modbus protocol. Link Modbus Poll : https://drive. In this tutorial, we'll show you how to download and install Modbus Poll software, a powerful Modbus master simulator that's essential for anyone working wit A modbus master and slave test tool with import and export functionality, supports TCP, UDP and RTU. Net control that makes it easy to access data from a Modbus slave device connected to the PC's Ethernet network. buy now. Aug 22, 2019 · 一、介紹 Modbus Poll :Modbus主機仿真器,用於測試和調試Modbus從設備。 該軟件支持ModbusRTU、ASCII、TCP/IP。 用來幫助開發人員測試Modbus從設備,或者其它Modbus協議的測試和仿真。 Single-User license - You may use a single-user license on any number of computers as long as only you are using it. To see the maximum polling rate achievable with the number of sensors created - 1. It can handle modbus exception code. The program uses the multiwindow mode for convenient display of various technical parameters in several tables at once. Go the the menu and select manage Palette and search for the node-red-contrib-modbus package. google. Instead of reading each register individually, the batch read function reads registers in manually created groups. Modbus Poll. The integration adheres strictly to the protocol specification using pymodbus for the protocol implementation. Oct 14, 2015 · Your problem is related directly to a windows application called Modbus Poll. New version 9 with Real time Charting. There will be minimal time required following a response Nov 27, 2023 · But instead of opening Modbus Poll, first open PuTTY again to confirm that there is no output from the DAT11 (a Modbus RTU slave should not transmit anything until it receives a request from the master). 29} EDIT: the modbus-tk library can be easily improved to reduce the CPU usage. Your highest priority registers will be polled most often by your RTU, while the registers with a lower priority are polled less often. The communication to the device/devices With many Modbus slaves you also need to be careful not to poll the slaves too quickly but the WattNode is more robust than most slaves are in this regard. Download. The system is like this: PIC24 -> UART -> IC MAX3471 -> RS-485 to RJ-45 converter -> RJ-45 to USB -> PC (running modbuspoll tool) The Modbus format used is Modbus RTU. Wisdom Software® https://c2verify. Home Assistant integration solaredge-modbus-multi supports SolarEdge inverters with Modbus/TCP local polling. The Modbus protocol specification is openly published and use of the protocol is royalty-free. The software can be used on a trial basis, which disconnects communication every 10 minutes. Requests from 2 slaves ID's. Base address: In the display menu you can select Base 0 or Base 1. 0. Select one of the 28 display formats from the display menu. (Protocol address 0 to 29 using Modbus function 03 Holding registers) Display with protocol style addresses. This is NOT a Modbus issue - it is an implementation issue. for example : mbpoll -t4:int /dev/ttyUSB0 -- 123 -1568 8974 -12 General options : -m # mode (rtu or tcp, TCP is default) -a # Slave address (1-255 for rtu, 0-255 for tcp, 1 is default) for reading, it is possible to give an address list Dec 11, 2023 · I am working with a Modbus device; and I could not get it to stay connected. The node were able to send modbus requests according to the established rule table. Modbus RTU and TCP ActiveX controls Feb 8, 2024 · Modbus polling to Power Meters through PAS with separeted network mode. 00. 1. A Modbus addressing model. Witte Software® https://www. MODBUS poll: How to make sure that the application sends requests and receives responses? Mar 16, 2023 · So, if you're familiar with Modbus or other traditional polling drivers in TOP Server, you may be aware that it is the client application (your HMI, SCADA or other application needing the data that is being requested) that causes TOP Server to send requests to your devices (this default behavior can be modified, though, using the TOP Server Mar 24, 2022 · Do note, that I also have used an Moxa Modbus RTU gateway in the very same setup (option B). When data are ready it fires a “DataReady_Event(EventArg data)” to all subscribers. > If not, is there a typical or average polling rate most vendors use? Not that I know of. Simply drop the control on your form and talk to your device with your VB. On the "Query Parse Filter" tab, select that module and click the "Setup" button to the right of the module name in the list. Modbus Poll display formats: Mark the cells to be formatted. As a rule of Mar 6, 2020 · Video này mình hướng dẫn dùng phần mềm Modbus Poll để đọc và ghi dữ liệu với bộ điều khiển ACP Bacnet của LG thông qua giao thức Modbus TCP/IP. Sep 23, 2022 · I have a working MODBUS TCP connection to an ESP-32 “slave” which is running the Arduino version of MODBUS-slave. or directly online with Rilheva Modbus Poll Web Edition. Poll for requests. The nodes that we are mainly interested in are the read and write nodes. zip (298 bytes) Modbus Poll is a useful software tool for testing Modbus RTU and Modbus TCP communication. Returns. com. 2023-03-24. However, it appears that he Home Assistant implementation of MODBUS (tcp) keeps the TCP connection to the device “open” after initial connection Feb 6, 2023 · Modbus Poll是一种广泛用于Modbus通信协议的测试工具,它允许用户模拟主设备(通常是客户端)与从设备(通常是服务器)之间的通信,以验证通信的正常性。在Modbus Poll的使用中,用户可能会遇到各种异常功能,这些异常功能对于故障诊断和问题解决至关重要。 Nov 19, 2023 · Modbus Poll user manual. 01. 057 seconds, and on a weaker computer this request is received in 0. Gateways performing transparent mode conversions are usually set up easily and quickly. This logic will measure and display the maximum achieved polling rate. Among others: Designers of Modbus slave devices for quick and easy testing of protocol interface. The low cost of memory now makes it feasible to use registers above 9,999 (decimal) with 6-digit addressing If you want to change the setpoint via Modbus, then read (4)16392 Mar 6, 2024 · MODBUS RTU, MODBUS ASCII, MODBUS/TCP. Schneider Electric support forum to share knowledge about product selection, installation and troubleshooting for EcoStruxure Panel Server, PowerTag, Com'X, Link150 Mar 8, 2022 · USB to RS-485이므로 컴퓨터 설정에 가서 COM 번호를 확인 한다. 1 on request, 0 on no request Oct 24, 2023 · There are a collection of modbus nodes available for node-red which you will need to install. A proven product, trusted by customers for over 20-years. 5. It is a de facto standard, truly open and the most widely used network protocol in the industrial manufacturing environment. This window shows 30 registers from 0 to 29. write. On others: Designers of Modbus slave devices on quick and single testing of protocol interface. 00 per license. be/IkMgzrr_cGk2. modpoll runs on Linux kernel 2. com/delta-ms300-modbus-rtu-via-modbus-poll/Please share and subscribe to the cha The first node we need to configure is the Modbus-read node, this can be found in the Modbus tab of your palette: The purpose of this node is to connect to a Modbus TCP device to read registers/coils values with a given polling rate. Modbus TCP Client (that is, as modbus master), querying data from Modbus TCP servers (that is, modbus slaves) Modbus serial master, querying data from modbus serial slaves; The Modbus binding polls the slave data with a configurable poll period. They feed standard OPC tags with hardcoded paths (e. 7 / Modbus Driver 6. DDS90: timeBetweenTransactionsMillis="0". Gateways and Energy Servers. Configure incoming Modbus/TCP masters (a message source). Arduino talks with the software on PC or app on the 1. Sep 11, 2018 · The Modbus Register Groups are a batch read function to poll Modbus devices. For example - I send a request on my computer 01 03 04 50 00 01 85 2B and received a response in 0. Scalability - Pros & Cons Feb 23, 2018 · Testing your modbus devices has never been so easy! Rilheva Modbus POLL is easy to use, fully configurable and provides reliable data. Modbus Poll communication traffic: Select the menu Display->Communication to show the traffic on the serial line or Ethernet cable. It can send "write request" command by input msg. Modscan 32의 경우 Master에서 Modbus polling을 해야하고. This window shows 30 registers from 40001 to 40030. The interval is the duration between successive rising edges of the REQ input to the Modbus_Master block. Show polling data for local debugging, like a typical modpoll tool. The device is the same and connected in the same way. For each network, the poll manager operates with a poll list and a poll task. Nov 15, 2016 · I am trying to implement a Modbus RTU system (PLC to 4 slaves) and have found it necessary to set the polling delay to 100mS for reliable operation. 0 or later, QNX RTOS 6. This can be ugly, as you may be able to poll 1 slave rapidly, but to switch to a new one, you may need to delay 50 or even 200msec. However, even using Modbus ASCII protocol takes some Modbus experience, and even if you know the unit ID and registers you'd like to poll, you will need to calculate the CRC for the message. During the same time, the other slaves do the same and will clear the buffer. Nov 12, 2021 · Modbus Poll & DELTA MS300 VFD Modbus-RTU via RS485Guide Link: https://plc247. 2) All slave receives the request : the message Q01 are in each slave buffer. There are 11 nodes in the package and they are grouped together in the Modbus section. Rilheva Modbus Poll is designed primarily to help developers of Modbus slave devices or others that want to test and simulate the Modbus protocol. Phần mềm Modbus Poll là phần mềm giả lập Modbus Master, phần mềm được thiết kế cho người lập trình Modbus Slave có thể thử nghiệm (test) hoặc mô phỏng giao thức Modbus. I was able to fix it by putting a tag in "Polling" mode. Modbus Poll Sep 12, 2017 · Options. It can be displayed in 4 different Modbus Poll is a Modbus simulator designed primarily to help developers of Modbus slave devices or others that want to test and simulate the Modbus protocol. Presumably you knowing the starting address and that the two inputs are contiguous; therefore you need to read quantity=2. Modbus Poll is a Modbus master simulator designed primarily to help developers of Modbus slave devices or others that want to test and simulate the Modbus protocol. This tutorial is about Arduino, so Arduino represents for the device. Price: 1 license: $ 129. Set all Modbus sensors to the The motor setting like the angle, delay, start/stop, duty cycle, etc will be sent from PC using Modbus to PIC24. This combines 2 16 Bit Modbus registers. Tuy nhiên, nếu các bạn đang lập trình cho thiết bị modbus slave và không có thiết bị master để test thì chương trình Modbus Poll sẽ là ứng dụng tuyệt vời để mô phỏng giống Jun 14, 2011 · Generally, the delay between polls has a few reasons. @avra is correct: you want to make sure your device can support Modbus ASCII if you'd like to use a Terminal to attempt to poll Modbus registers. Modbus Function Codes. 28 display formats; Log data directly into Excel; Writes data to text file (text file) Monitoring of serial data traffic; Read / write up to 2000 Inputs / Coil Scroll to top. fv lm hg nc mr jo ev hk lc wm

This site uses Akismet to reduce spam. Learn how your comment data is processed.