Настенный считыватель смарт-карт  МГц; идентификаторы ISO 14443A, смартфоны на базе ОС Android с функцией NFC, устройства с Apple Pay

Pellet stove trim adjustment

Pellet stove trim adjustment. This pellet heater needs periodic inspection and repair for proper operation. View and Download Harman P68 owner's manual online. Aug 21, 2023 · The Castle Serenity Stove 12327 is another top-tier pellet stove option that deserves praise. 23 for feed motor troubleshooting. Proper Shutdown Procedure. The Westpoint has been tested and listed for installation in residential and mobile homes. Dec 2, 2019. Heats 2,800 sq. This stove is a show piece with its curved black sides and flat black accents. com Oct 30, 2012 · Depending on fuel type and moisture content, your fire may need adjusting. 85 MB. Top-mounted 55 lbs. Properly maintaining your pellet product can extend the life of the unit as well as its parts, giving you a better heating experience. But I only like to see it on start-up. Like the HP22, it's one of the most powerful and cleanest burning pellet stoves sold in North America today. Let me know how this works for Trim Adjustment. A large ash collection area and 130-pound hopper help provide heating convenience. If necessary, clean or replace it. • Excessive sooting pelprostoves. Boost Your Breckwell- Run on Heat Level 1 without Re-adjusting the Damper. com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment. to adjust the amount of combustion air for the re. Operating Your PelPro Stove. The Comfort Bilt HP22N has all the features of the HP22 pellet stove plus a hopper that holds 45% more pellets. An efficient flame has an active appearance and a bright orange or yellow color. The 1 red blink would mean the stove think that the hopper is empty so the fire went out. Pelpro PP130-B Pdf User Manuals. com PelPro Pellet Stove • 8104-171B • 10/21 Page 18: Warranty All replacement parts are covered for remainder of original warranty 90 Days period or 90 days, whichever is longer Additional terms and limitations apply. com PelPro Pellet Stove • 714-171I • 6/21 3 Get to Know Your PelProGet to Know Your Stove® Stove Safety First! California - Prop65 Safety Alert Key: It is important to pay attention to alerts you will see throughout this manual to ensure your safety. The holes in the burnpot may be getting filled of pellets due to a patented feeder and burn pot sys- with ash or carbon buildup. Frequently check your stove and adjust the slider/damper as needed to ensure proper combustion. 185 bags Cubex 35 bags ecolo nature. I have previously owned a Harman Accentra insert and a Quadra Fire Mt Vernon insert, and I am accustomed to moderate soot on the glass, but the soot blacks out 1/2 stove. If the stove has excesses ash build-up in the liner on the higher settings the Feed Rate Trim should be Review the installation and move if necessary. Using a 5/16 inch wrench, on each side of the Stove remove the two bolts. Replacement kit: 812-4400 PelPro Pellet Stove • 7083-801F • 04/21 pelprostoves. See Maintaining and Servicing page 14 and/or make adjustments to the trim control. Page 14: Maintenance And Service Oct 16, 2012 · FEED RATE TRIM BUTTON: Used to change the feed rate trims in ¼ second increments for all. With a hopper that holds 45% more pellets than the HP22, it sets a new standard for convenience. Maintaining a clean UltraGrate™ is vital to the safe and efficient operation of the stove. If the fire is orange and reddish in color with soot forming at the top of the flame, open the damper slowly. View online or download Pelpro TSC90 User Manual, Manual. Buy Parts Now. When you first start the stove, it should be placed in the “OFF” position in order to heat the unit as quickly as possible. Pellet Stove. To increase the low air burn number press the up arrow buttons below the heat range and blower speed. The P68 is capable of burning all u0018 categories 4. Dec 4, 2010 · 81. EPA Certified Pellet Stove in Brown and SS Trim The ComfortBilt HP22N in Brown with Stainless Steel trim is one of our most powerful pellet stove models. Fuel & Fuel Storage for Your PelPro Stove. Table of Contents. Jan 2, 2022 · Solution: Start cleaning the complete parts of the stove, including the firepot, burn grate, and chimney pipe. If it is a black soot build up airflow through the unit may be restricted. Ignition Problems. the stove will need to complete a shutdown sequence for the setting to take effect. When I light it in the morning (after cleaning the front end) I have to turn the combustion air up a bit (trim pot) then after the stove warms up to some sort of operating temp I have to turn it down or the occasional pellet jumps out of Jan 18, 2020 · FEED RATE TRIM BUTTON: Used to change the feed rate trims in 1⁄4 second increments for all feed settings. One key aspect is increasing insulation to minimize heat loss. To adjust the setting. #1. Step 3. such as high salt content. Or call us right now about your heating needs: 046 943 6702. View online or download Pelpro PP130-B Owner's Manual. Robust Design made with Heavy Gage Steel. If there is a problem with the hopper and vacuum switches, either repair them or replace them. Thank you for purchasing the Westpoint pellet stove. This heater has been certified to ASTM E1509-04 Standard Specification for Room Heaters, Pellet Fuel-Burning Type. hopper will keep stove burning continuously up to 24-hours. When this button is pressed, all the light will light up on the Heat Output Indicator except for the one that shows the current setting; the default setting is the number 4 light. Pellet heaters work by using a software Designed for customers who enjoy the look of a traditional log-burning stove, the ComfortBilt HP61 is one of the most powerful and cleanest burning pellet stoves sold in North America today. The air inlet setting gives you more control over the temperature of the fire in the stove. The reasons are not very complicated. Nov 25, 2021 · How to adjust your pellet stove to fine tune your burn rate. Insulating the walls, ceilings, and floors of your home can prevent heat from escaping, ensuring that the warmth generated by the stove stays inside. If the flame appears to burn very quickly and too close to the bottom of the stove or appears to burn slowly and almost touches the top of the stove, adjust the air intake. The lowest and highest heat levels on this pellet stove are used for adjusting and accommodating for different pellet sizes and the varying energy produced by the fuels. It is advisable to inspect and All replacement parts are covered for remainder of original warranty 90 Days period or 90 days, whichever is longer Additional terms and limitations apply. com PelPro Pellet Stove • 7103-171N • 08/23 3 Get to Know Your Stove California - Prop65 Get to Know Your PelPro® Stove Safety First! Safety Alert Key: It is important to pay attention to alerts you will see throughout this manual to ensure your safety. need MORE air. If the glass has white ash build up it is normal and the glass should be cleaned. A simple dial control makes it easy to stay warm, and a 70-pound hopper delivers Oct 2, 2021 · Pelpro pp130 draft/trim help. Y ou. In general terms a standard pellet is 1/4" in diameter and should range from ½" to 3/4". PELLET FEED RATES: Due to different fuel densities and sizes, pellet feed rates may vary. The flame can "lick" the top baffle plate here and there. May 31, 2022 · Watch this short video to learn about how to use your QuadraFire Outfitter Series Pellet Stove We have just the right product for your home. Keep viewing doors tightly closed during operation. PelPro Cast Pellet Stove • 7093-600J • 04/21 pelprostoves. Using a 7/16 wrench or socket, remove the 2 nuts holding the blower to the convection plenum. com pelprostoves. Locate the thin white wires coming from the top right side (looking at the board from the rear) and follow them to the igniter. Keep viewing and ash removal doors tightly closed during operation. Quick Reference Maintenance Chart. Flame on that steel may cause warping. Browse the Eco Home Solutions range of competitively price wood stoves and fireplaces – here on the website, or call in – we’re handily placed right in Trim town centre. 2. Nov 8, 2008 · Whitfield Advantage II-T; adjust auger trim. Unplug the stove and remove the back panel. We believe that quality and style aren’t mutually exclusive, and that form shouldn’t follow function—they should arrive at the same time. (78) Questions & Answers (30) Heat Exchange Design Allows for Maximum Heat Output. The performance of your pellet stove is greatly affected by the type and quality of fuel being . See: “Slider/damper Setting”. Ventilate the stove 1/8 of an inch at a time until the fire is 2 PelPro Pellet Stove • 783-81K • 8/23 pelprostoves. Remove shipping brackets by reaching into Stove in the same area as the just removed bolts. click here or see pg. Watch to learn more Jan 31, 2019 · Try to start the stove again. After all, its heating area is up to 1,500 sq. If you don’t have ignition within 5 minutes, your Englander pellet stove igniter needs adjustment. • • DANGER! Dec 12, 2009 · Tried the trim adjustment and it worked (actually a little too well-- ran out of pellets this morning and the fire went out-- will put the setting halfway between. When allowing more air into the pellet stove, temperatures will be hotter. Products with Acutron Control. 35K subscribers. There’s not enough air running through the burn pot to blow all the ash out so it kind of starts piling up. KeiBow. 29 MB. 12. Lift the lever on burn pot to unlock the fire grate and remove it. The trim adjustment may actually help in this situation. Although every Dec 21, 2022 · ComfortBilt. For earlier PelPro models, the name of the control board is printed on the face of Solid Fuel Room Heater/Pellet Fuel Burning Type Standard: ULC S627-00 Room Heater Pellet Fuel Burning type and (UM) 84-HUD, Mobile Home Approved. If set properly, the baffle plate is just at 6" over very top level of firepot. Dec 14, 2014. You did have to also mess with it but at least it was more straight forward and had more noticable effect than the pelpro and the trim pot. NOTE: New stoves can emanate an odor during the initial few hours of burning while the paint cures. Home, sweet home, just got sweeter. Observe the flame height after approximately 15 minutes with the new effect your pellet stoves operation in several ways. Older stoves have a buildup of calcium, iron and carbon deposits on the inside walls of the internal ash chambers. #2. The flame reacts differently according to the quantity of air that feeds it. If it does not work, replace it. com PelPro Cast Pellet Stove • 7093-600J • 04/21 require an adjustment to the slider damper setting or to the auger feed trim setting on low. 4. May 17, 2023 · 1. To start loosening the bolts then you close the door quietly and you adjust this might take several shot. Dec 14, 2014 · Val-d'Or Québec. air flow bad pellets black glass pelpro. Check for degradation on the gasket and replace if necessary using the gasket included in the kit. Also how I set it up through a wall and i show thermostat hookup. Dec 19, 2015. Press the center button on the bottom of the control panel, labeled "Low Air Burn. PELLET FEED RATES:Due to different fuel densities and sizes, pellet feed rates may vary. the Heat Output Indicator except for the one that shows the current. Tami Lorene. If the thermostat mode is off or the doors are open, your Enviro pellet stove won’t light. PELPROSTOVES. Hey guys this is my PelPro Pellet Stove PP130 set up and trim settings. 24K views 3 years ago. Since Hudson River Stove Works has no control over the quality of pellets that you use, we assume no liability for your choice in wood pellets. Raise the rod only about ¼” with each adjustment, and retighten the thumbscrew each time. 1% EPA Certified efficiency insure that you'll get the maximum amount of heat from each pound of pellet fuel you use. Oct 31, 2012 · Depending on fuel type and moisture content, your fire may need adjusting. This durable, high-efficiency (87. As with any device that depends on a flame to produce heat, though, the ratio of oxygen to fuel needs to be The Negative Side of the Trim Adjustment will decrease the feed rate of the feed motor and increase the RPM of the exhaust blower. I had a pellet stove years ago, forget the brand, in a house I owned and it just had a dial for the pellet feed control and that was it. P68 pellet stove pdf manual download. The smaller and shorter a pellet is the faster it will feed into the stove and the larger Dec 1, 2010 · ENVIRO M55 trim settings? mutsuura. You must press both of the up arrow buttons at the same time to adjust the number. 11. , in accordance with UL®-641 Standard for Low Temperature Venting Systems, as well as the applicable requirements from UL®-103 Standard for Residential Type and Building Heating The Feed Trim button pressed in conjunction with the Heat Level adjustment buttons to adjust the Feed Trim. Harman P68 installed 12 february 2014. BACKGROUND: SILVER 2. EPA certified to be safe and to meet all US emissions requirements. once the stove is running did the 1 flash: empty hopper code repeat? check 3: click here or see pg. PelPro Pellet Stove • 8104-171B • 10/21 pelprostoves. It comes with a 46 Lb. Breckwell Pellet Stoves sometimes have trouble running on heat level 1, especially when they get older. Make sure #1 trim pod is set to 9 o’clock position Air inlet damper is OPEN to between 1/4” and 1/2” 4 Adjust FUEL RATE and FAN SPEED to your desired settings (see PELLET STOVE ADJUSTMENTS section). 7. Quadrafire stoves do have a tendency to overfill the burn pot when running on low from my experience. The all digital control system comes with a temperature readout and a remote control for simple adjustments. Please consult your PelPro manual or the videos found in the Use & Care section for proper maintenance instructions. Its high CFM convection blower and 80. It has 5 heat levels that can be adjusted manually or by programmable thermostat, and quiet high-CFM convection fan to make sure that maximum heated air is delivered to your Remove the right side panel by loosening the three screws attaching it to the back of the appliance. This seems to be a new development with my Whitfield Quest Plus. The air inlet setting on a pellet stove permits you to allow more or less air into the unit. This is exacerbated at 3 AM when the diurnal 2 PelPro Pellet Stove • 714-171M • 8/23 pelprostoves. Pellet Size Size of the pellet in both diameter and length will effect the amount of fuel your stove will burn. Open the door using the door handle located on the right-hand side of the stove. 2 PelPro Pellet Stove • 7103-171N • 08/23 pelprostoves. Engineered and constructed to the highest Nov 29, 2021 · Here are the five enviro pellet stove issues and their easy solutions. pelprostoves. • • DANGER! Feb 21, 2016 · If appliance has long horizontal venting sections or more than two 90 degree Elbows: QuadraFire recommends starting at a -4 trim setting and making adjustments based on fuel type and elevation. 020 THICK 2. Manuals. One reason for this is the high heat output that makes it suitable for larger rooms and houses. The simple dial control makes it easy to stay warm. Feb 22, 2011. adjustment. The performance of your pellet stove can be affected by the type of pellet fuel burnt in . So it shouldn't hit it often. com Page 11: Venting Your Stove • Your Stove will not draft properly that can build up a concentration of fumes such as a stairwell, • Smoke may seep in your house covered breezeway, etc. has no control over the quality of pellets that you use, we assume no liability for your choice in wood pellets. 2024 Catalog. The high efficiency can be attributed to the use of high quality pellets and the unique features such as the blower and trim adjustment. Our VP Pellet Pipe has been tested and listed by Underwriters Laboratories, Inc. Pellet stove Stove Indoor Hearth & Home Technologies reserves the right to update units periodically. 2 days ago · Selkirk® gives you the safe, efficient, and cost-effective pellet venting system that's engineered precisely for pellet burning stoves. I am using Tractor Supply pellets this took a few weeks to get totally dialed in with my Feb 26, 2021 · Pelpro pp 130 trim settings this is what I found out. View Full Product Details. ft. Install the burner grate correctly. PelPro Pellet Stove • 7104-171C • 10/3/18 pelprostoves. This will vary due to the ash content of the fuel used and the operation of the stove. Visit pelprostoves. To adjust the setting hold the Feed Rate Trim button down PelPro Pellet Stove • 7086-171O • 2/20/18 pelprostoves. GROWING EDIBLE PLANTS 👍🌱. See page 30 for complete warranty information. Check for signs of fuel other than wood pel- lets. com PelPro Pellet Stove • 714-171M • 8/23 3 Get to Know Your PelProGet to Know Your Stove® Stove Safety First! California - Prop65 Safety Alert Key: It is important to pay attention to alerts you will see throughout this manual to ensure your safety. 1. From our testing, we have found that -4,-3, +3, or +4 have worked well depending on fuels. you also test the dollar bill up time either ok. As the heat output of various quality fuels differs, so will the performance and heat output of the pellet stove. T o decrease the amount of. DAMPER ADJUSTMENT The Montage™ pellet stove is equipped with a damper which is used to fine tune combustion. PP70 stove pdf manual download. Apr 25, 2018 · Pleasant Hearth PH50CABPS [12/132] N trim adjustment. com PelPro Pellet Stove • 7104-171C • 10/3/18 Dec 2, 2019 · 2. 12K views 1 year ago. A properly adjusted fire provides maximum efficiency and heat. RETAIN YOUR ORIGINAL RECEIPT FOR ANY WARRANTY 1-2 hours could lead to potential overheating situations. 2 PelPro Pellet Stove • 714-171I • 6/21 pelprostoves. com or scan the code: Loosen the three retaining bolts on the back of the Stove and remove the right and left side panels. If you need help in determining the product that best suits your needs, please see your local authorized dealer. They are convenient, because automatic pellet feeders and adjustable thermostats make them as easy to operate as a standard gas or electric heater. yes it is easy to adjust. To solve this issue, start by inspecting the igniter for any build-up or corrosion. We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues. com Page 24: Troubleshooting Unplug your Stove Zone Zone • Check all connections and power plugs are secure Zone Zone Zone Zone • Visually inspect wires, blowers and power cord to find cause of possible short circuit PelPro Pellet Stove • 7086-171O • 2/20/18 pelprostoves. The Trim button is used to adjust the Exhaust (Combustion) fan voltages up or down to provide for fine-tuning of the combustion air. I recently bought a Quadra Fire Trekker pellet insert and have been sorely disappointed by the overwhelming amount of soot buildup on the glass. Aug 22, 2012 · Pellet stoves are designed to burn cleanly and efficiently, saving money and reducing the amount of smoke and soot distributed in a home. Try adjusting it up a small amount to allow more air and see how it does. Our products are built to last and are backed by the require an adjustment to the slider damper setting or to the auger feed trim setting on Low. hopper to provide up to 32-hours of burn time between fillings. Also, the stove could be unplugged by mistake, and an unplugged stove will not light at all. It is against federal regulations to operate this pellet heater in a manner inconsistent with operating Check the stove for ash build up (clean if required) and adjust the combustion air trim and if required the slider/damper to produce the proper clean combustion. CLEANING: There will be some build up of fly ash and small amounts of creosote in the exhaust. About Breckwell Hearth. com PelPro Pellet Stove • 783-81K • 8/23 3 Get to Know Your Stove Table of Contents Get to Know Your PelPro® Stove NOTE: REV REVISIONS ECO # A RELEASED 72901 B ADDED WWW. Clean the feed motor properly. If your re is too small and sometimes goes. We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense Jan 10, 2011 · combustion air on whitfield profile 30. With up to 49,200 BTUs and a 265 cfm blower (standard), the EPA-Certified PP150 will heat up to 2,500 square feet. PelPro Use and Care Videos for Products with Acutron Control. Dec 19, 2015 · Pelpro 130 pellet stove won't stay lit. MATERIAL: NON-ANODIZED ALUMINUM 0. A pellet stove's advanced settings will allow you to adjust the fuel feed rate, burn Pallet Removal. system is repaired are the wires plugged into the blower? no yes make the repair by cleaning or replacing the blower or by replacing the control board. Active since 1995, Hearth. Been playing around with the trim settings on my adjust the trim setting to the positive or clockwise position. COM 75290 1. burned. Page 25: Electrical Diagram ELECTRICAL DIAGRAM ELECTRICAL DIAGRAM FIGURE 21 Page 26: Replacement Parts List Dec 5, 2020 · 2,800 sq. CAUTION: It is important to select and use only fuel that are dry and free of dirt or any impurities . Superior firebox design and heat exchanger produce up to 41,000 BTUs per hour. installed oak january 2015. Brand: Pelpro | Category: Stove | Size: 13. 5%) pellet stove is built for extended performance. too much air (too lean). Additionally, you can adjust the air intake adjustment lever located on the bottom-front of the stove to regulate the amount of combustion air being fed to the pellet fire pot. One common issue with Castle Serenity pellet stoves is ignition failure. Practical and high-efficiency heating comes easy with the PP70 stove. Stove Not Lighting. This stove has been independently tested to ASTM E1509-12 (2017) Standard Specification for Room Heaters, Pellet Fuel Burning Type 1, ULC-S627 Standard for Solid Fuel Room Heaters, and Oregon Administrative Rules for Mobile Homes (814-23-900 through 814-23-909) and Installation as a Stove Heater. It is a good idea to verify your UltraGrate is clean prior to ignition each time you operate your stove. Notably, the hopper in this machine can hold a maximum of 40 lbs of pellets. com PelPro Pellet Stove • 7083-801F • 04/21 Page 15: Troubleshooting 4. With the blower removed, unplug its wires from the wire harness. When this button is pressed, all the light will light up on. Trim should be increased one setting at a time until the problem improves (Factory Setting is #2). Leominster, MA. We make premium hearth products designed with discerning tastes in mind. Caleb90. Fuel other than wood pellets is being burned in the stove. Follow these 8 steps to adjust your igniter. Nov 8, 2008. require an adjustment to the slider damper setting or to the auger feed trim setting on low heat levels. To shutdown, turn dial control to OFF or set thermostat below room temperature. com for videos on troubleshooting your PelPro appliance. May 3, 2024 · To maximize heat output in a wood pellet stove, it’s important to use efficient airflow techniques. T o increase the amount of combus-. It can heat up to 2,200 sq. Top Mounted Hopper Lid for Easy Access. These principles apply to many pellet Nov 7, 2023 · To increase the air flow in your pellet stove, you can turn the trim clockwise to increase the feed rate and prevent the fire from going out. Feb 22, 2019 · Tim from Friendly Fires walks us through the basics of setting the draft control (air flow) on an Enviro Pellet Stove. The LED lights indicate the level of adjustment and the factory setting is the center LED light. No 2 stoves will have the same setting. For further instruction refer to owner's manual. Nov 28, 2022 · 54. Feb 1, 2010 · A change in pellet will require a slight adjustment. • DANGER! Start by evaluating the quality of your flame. Thanks very much for the help! Tim The stove’s efficiency is unquestionable: Pelpro Pellet Stove is EPA approved and has been rated at 85% efficiency. The most often cause is overdue maintenance and cleaning. This may require an adjustment to the slider damper setting or to the auger feed trim setting on low. By adjusting the damper, you attempt to give the flame the right amount of air in order to allow it to burn efficiently. or more, depending on outside temps, insulation, and room layout. We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense Aug 28, 2012 · Observe the flames inside your wood pellet stove. setting; the default setting is the number 4 light. Brand: Pelpro | Category: Stove | Size: 11. It can be increased by two (2) feed settings or it can be decreased by two (2) feed settings. 4 Maintaining & Servicing the Appliance. Pelpro TSC90 Pdf User Manuals. CONVECTION BLOWER SPEED CONTROL (KNOB A): By adjusting the knob you will vary the rate of airflow into the room by varying the speed of the convection blower. (check if any led lights are on) unplug the stove, install wires back on the blower and restart the unit. Having a proper flame is the easiest way to ensure that the stove is operating properly. New Fairfield, CT. 3. is the blower running? yes no dial control pellet stoves troubleshooting manual Visit www. set thermostat above room temperature, the stove will light automatically. Subscribed. Adjusting it all the way down changed it from about every 7 seconds to just over 8 between rotations. feed settings. Read page 1 of our customer reviews for more information on the ComfortBilt HP22N Pellet Stove 2800 sq ft EPA Certified in Black. This will give your stove less pellets and more air. If the fire is going out on low because the airflow is too great, the Combustion Blower Trim can be lowered to the #1 setting. View and Download Pelpro PP70 owner's manual online. This problem can arise due to various reasons, such as a dirty igniter or a malfunctioning control board. The flames should be bright yellowish-orange and burn without producing a black tip along the top of the flame. Watch to learn more Sep 25, 2021 · If the flame is too hot, it will lead to the unwanted popcorning effect, where the pellets that are glowing with potential fire shoot out of the opening of the pellet stove. Breckwell pellet stoves are designed and tested to use wood pellets. Dec 1, 2010. Oct 22, 2017 · On Original Energy stoves, to allow more pellets into the firepot on each feed, increase the feed rate by loosening the thumb screw on the feed rate adjustment rod inside the hopper. " The control panel will display the number the low air burn is at. Lower the back of the blower and lift out. Mar 15, 2017 · Mar 15, 2017. 10 for trim adjustment guide. May 11, 2013 · This video shows the flame patterns on an Enviro M55 pellet stove. Products with Dial Control. Re-install in reverse order. Once Dec 13, 2021 · The only adjust on these stoves that I am aware of is the trim adjustment located below the comfort/control dial. Dec 25, 2022. Using Your PelPro Stove for the First Time. Store pellets at least 36” (1 m) away from the pellet stove. Jan 14, 2018 · After I did my cleanup and work on the auger it is running best on +2. AUTOMATIC SAFETY FEATURES: Pelpro TSC90 Manual (21 pages) Cast Iron Pellet Stove. 134. Since Sherwood Industries Ltd. ev zo pd zq re ti xy ri zl ny